- Roles
- Competent person
- Authorised inspection body
Operator, maintainer, competent person: who does what?
Operator, maintenance contractor, competent person, authorised or notified body: the roles in in-service monitoring of pressure equipment, per the texts.
By cDESP team6 min read
A question that comes up on every job
"The refrigeration technician takes care of it." This sentence, heard on many sites, sums up a common misunderstanding. The maintenance contractor (mainteneur) does a large part of the work, but the regulations do not give it responsibility for in-service monitoring. They give it to the operator (exploitant).
Here, with the texts to back it up, is who does what in the monitoring of the pressure equipment (ESP, équipements sous pression) of a refrigeration installation. References are to the arrêté du 20 novembre 2017 relatif au suivi en service des équipements sous pression (French ministerial order of 20 November 2017 on in-service monitoring of pressure equipment), unless stated otherwise.
The operator: the one who carries the responsibility
The order defines the operator as the owner of the equipment, its agent or its duly appointed representative (article 2). In a cold store, this is generally the company that owns the installations, not the maintenance company.
Its main obligations:
- define the conditions of use of the equipment, taking into account those provided by the manufacturer (article 4);
- have the necessary staff and provide them with the relevant documents, and provide the human and material resources for inspections (article 5);
- draw up, keep up to date and retain the operating file (dossier d'exploitation) for each item of equipment, and keep the equipment list (article 6);
- file the commissioning declaration when required, through the dedicated online service (articles 7 to 9);
- designate the competent person and carry responsibility for the inspection plan (articles 2 and 13).
The operator can delegate tasks by contract. It does not delegate its regulatory responsibility.
The competent person: the technical know-how
The "competent person" (personne compétente) is a precise notion of the order (article 2). It is a person designated by the operator and able to:
- check, during installation, that the equipment and its accessories remain compliant with the essential safety requirements;
- carry out an intervention;
- recognise defects and assess their seriousness during the periodic inspection, or the check after a non-significant intervention;
- draw up the inspection plan under the operator's responsibility;
- validate the correct implementation of the provisions of a professional technical code.
In practice, it is very often a technician or engineer from the maintenance contractor, sometimes an employee of the operator. What matters is the designation: it must exist and be traceable. The order also provides that the administration may reject a competent person if it considers that the person does not meet this condition (articles 11 and 17).
For installations monitored under the professional technical code (CTP, cahier technique professionnel) "Systèmes frigorifiques sous pression" (pressurised refrigeration systems), the CTP sets its own requirements for the people who carry out the initial verification and periodic inspections. The DREAL Hauts-de-France leaflet on the 2020 CTP referred to a person authorised by their employer. Check the exact wording of the 2026 version you apply.
The maintenance contractor: a service provider, not a regulatory category
The word "mainteneur" does not appear as a defined role in the order. The maintenance contractor works under its contract with the operator. Depending on that contract, it may:
- be the organisation to which the designated competent person belongs;
- carry out the periodic inspections, the non-significant interventions and keep the log;
- prepare the inspection plans, organise appointments with the authorised inspection body, warn of due dates.
The point to watch is simple: everything the maintenance contractor does must end up in the operator's file. If the reports stay in the service provider's archives, the operator has no file, and a change of maintenance contractor becomes a loss of memory (see our article on handing over the file).
The authorised inspection body: reserved inspections
Authorised inspection bodies (organismes habilités) are authorised by the State to carry out certain in-service monitoring operations. In refrigeration, you mostly meet them for:
- periodic requalification, carried out under the responsibility of an authorised inspection body (article 23), which issues the certificate and applies the so-called "horse's head" marking (tête de cheval) on equipment other than piping (articles 24 and 25);
- approval of the inspection plan (article 13);
- the inspection after a significant intervention (article 28);
- a few periodic inspections and commissioning inspections reserved for certain equipment (steam generators, vessels with quick-opening removable covers, coated equipment not stripped bare), rare cases in refrigeration.
The notified body: manufacturing, not monitoring
Notified bodies (organismes notifiés) and authorised inspection bodies are often confused. The notified body is involved in conformity assessment during manufacturing, under Directive 2014/68/EU (the Pressure Equipment Directive, PED). Its identification number follows the CE marking when it is involved in the production control phase (article 19 of the directive). The authorised inspection body is involved in in-service monitoring, once the equipment is installed. The same company may wear both hats, but the tasks are not the same.
The manufacturer and the installer
The manufacturer draws up the EU declaration of conformity, applies the marking and provides the instructions (Directive 2014/68/EU). The installer or assembler hands the operator the documents that feed the operating file. They must be demanded at acceptance: obtaining them years later is much harder.
The administration and other players
- The DREAL (regional environment authority; DRIEAT in Île-de-France, DEAL in the overseas territories) supervises the equipment in service, the authorised inspection bodies and the market (Ministry for the Ecological Transition).
- The BSERR (Bureau de la sécurité des équipements à risques et des réseaux), an office of the ministry, approves in particular the guides and professional technical codes, such as decision No. 2026-002 approving the 2026 CTP.
- La Chaîne Logistique du Froid is responsible for the CTP "Systèmes frigorifiques sous pression" and receives feedback from the operators who apply it.
Summary table
| Operation | Who carries it out | Reference |
|---|---|---|
| Keep the list and the operating file | Operator | Art. 6 |
| Commissioning declaration | Operator | Art. 7 to 9 |
| Commissioning inspection (usual cases) | Competent person | Art. 11 |
| Draw up the inspection plan | Competent person, under the operator's responsibility | Art. 13 |
| Approve the inspection plan | Authorised inspection body | Art. 13 |
| Periodic inspection (usual cases) | Competent person | Art. 17 |
| Periodic requalification | Authorised inspection body | Art. 23 to 25 |
| Non-significant intervention | Operator or a competent person it designates | Art. 29 |
| Inspection after a significant intervention | Authorised inspection body | Art. 28 |
The provisions of a CTP may organise these operations differently for the equipment it covers (initial verification, content of inspections, approval of the plan at requalification). The CTP applied is authoritative on these points.
Three reflexes to avoid gaps
- Put the roles in writing: who the competent person is, which authorised inspection body, who keeps the file. One page is enough, dated and signed.
- Centralise the documents with the operator, even when the maintenance contractor produces them.
- Review the roles at every change: new contract, departure of a technician, sale of the site.
Where cDESP fits in
cDESP serves as a shared space between these players: the operator keeps its sites and documents, the maintenance contractor works in it for several clients, appointments with authorised inspection bodies are scheduled with confirmation and a reminder the day before, and inspections (initial verification, periodic inspection, inspection plan) are carried out and signed in the tool. The data remains the operator's.
To organise your roles and documents in one place, create an account or see the pricing.